Oscillated Needle System to Reduce Stress, Pain Response, Heel Damage and Developmental Harm from Recurring Heel Sticks in Neonates

Information

  • Research Project
  • 9131581
  • ApplicationId
    9131581
  • Core Project Number
    R41HD088139
  • Full Project Number
    1R41HD088139-01
  • Serial Number
    088139
  • FOA Number
    RFA-HD-16-028
  • Sub Project Id
  • Project Start Date
    5/18/2016 - 8 years ago
  • Project End Date
    4/29/2017 - 7 years ago
  • Program Officer Name
    RAJU, TONSE N.
  • Budget Start Date
    5/18/2016 - 8 years ago
  • Budget End Date
    4/29/2017 - 7 years ago
  • Fiscal Year
    2016
  • Support Year
    01
  • Suffix
  • Award Notice Date
    5/20/2016 - 8 years ago
Organizations

Oscillated Needle System to Reduce Stress, Pain Response, Heel Damage and Developmental Harm from Recurring Heel Sticks in Neonates

? DESCRIPTION (provided by applicant): This Phase I STTR - in response to RFA-HD-16-028 Non- or Minimally-Invasive Methods to Measure Biochemical Substances during Neonatal and Perinatal Patient Care and Research - develops and tests Baby Gentle Stick (BGS), a handheld device to decrease the distress of repeat blood sampling in neonates. BGS combines delivery of vibration-induced anesthesia with oscillated lancet insertion to reduce heel stick pain Blood collection in neonates is routinely necessary, with heel sticks (penetration of capillary bed with a sharp) being the most common technique for small samples (< 200 µL). Heel sticks are one of the most frequent painful procedures performed in the NICU, resulting in a repeated pain response, believed to negatively impact development. The pain associated with heel sticks has stimulated a multitude of studies aimed at developing strategies to alleviate discomfort, including the use of oral sucrose, glucose, non-nutritive sucking, kangaroo care/skin-to skin contact, electrical stimulation, white noise, breastfeeding, music, and massage. Moreover, clinical and laboratory studies suggest that preterm neonates are especially vulnerable and can exhibit sensitization to repeat stimuli. Recently, evidence for developmental plasticity in the neonatal brain suggests that repetitive painful experiences during this period or prolonged exposure to analgesic drugs may alter neuronal and synaptic organization permanently. The significance of this STTR is that a device is needed that provides drug-free reduction of the pain response, while simultaneously improving success rates and sample volumes, eliminating multiple attempts and reducing tissue damage. The innovation of this STTR is the combination of vibration-induced anesthesia with high-speed automatic lance in a single handheld device that lances with less pain and trauma, without compromising blood sample quality or volume. Baby Gentle Stick achieves these aims and meets the NIH/NICHD goal of Innovative ideas to reduce stress for the staff, parents and infants in the NICU (2015 SBIR/STTR Program Descriptions). Phase I Hypothesis. The pain response from the lancing event will be lessened with BGS, leading to less stressful heel stick blood collection in neonates than current practice. Specific Aims. Aim 1 - Development of BGS with mechanical performance verifications (AMI & Penn State University College of Medicine (PSU), Month 1-6). Acceptance Criteria. BGS hand piece meets all design requirements, including being battery-operated, be compatible with a commercially-available non-blade lancet, achieve vibration and reduction of force performance, and incision consistency. Aim 2 Demonstrate BGS reduces pain of standard heel sticks (AMI & PSU, Month 4 and 8-12). Acceptance Criteria: a) Pilot Human Study with 20 Healthy Adult Volunteers shows no adverse events, reduced pain, and receives positive clinician review, b) neonatal study (n=20) demonstrates reduced pain response (facial pain scores and skin conductance response data) while yielding functionally equivalent blood samples.

IC Name
EUNICE KENNEDY SHRIVER NATIONAL INSTITUTE OF CHILD HEALTH & HUMAN DEVELOPMENT
  • Activity
    R41
  • Administering IC
    HD
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    273508
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    865
  • Ed Inst. Type
  • Funding ICs
    NICHD:273508\
  • Funding Mechanism
    SBIR-STTR RPGs
  • Study Section
    ZHD1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    ACTUATED MEDICAL, INC.
  • Organization Department
  • Organization DUNS
    791379030
  • Organization City
    BELLEFONTE
  • Organization State
    PA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    168238445
  • Organization District
    UNITED STATES