Point-of Care System for Determination of Bilirubin Capacity in Neonates

Information

  • Research Project
  • 8502257
  • ApplicationId
    8502257
  • Core Project Number
    R44EB015924
  • Full Project Number
    5R44EB015924-03
  • Serial Number
    015924
  • FOA Number
    PA-11-096
  • Sub Project Id
  • Project Start Date
    7/1/2010 - 14 years ago
  • Project End Date
    2/28/2015 - 9 years ago
  • Program Officer Name
    LASH, TIFFANI BAILEY
  • Budget Start Date
    7/1/2013 - 11 years ago
  • Budget End Date
    2/28/2015 - 9 years ago
  • Fiscal Year
    2013
  • Support Year
    03
  • Suffix
  • Award Notice Date
    6/13/2013 - 11 years ago
Organizations

Point-of Care System for Determination of Bilirubin Capacity in Neonates

DESCRIPTION (provided by applicant): Uncontrolled hyperbilirubinemia (jaundice) in neonates has long been known to lead to neurological dysfunction including irreversible athetoid cerebral palsy with speech, ocular and hearing impairments, and even death. Contemporary management is based upon monitoring the total serum bilirubin (TBS), taking into account other clinical parameters such as birth weight and gestational age, and administering effective treatment (phototherapy and/or the rare exchange transfusion), if dictated. Unfortunately, the trend towards discharge of apparently healthy neonates from the hospital very soon after birth has made the management of subsequent jaundice more difficult in that population. A long suggested, but not used, better predictor of the neonate's risk for neurological sequelae due to elevated bilirubin is a measure of the capacity to sequester bilirubin in the blood compartment by its binding to serum albumin. The concentration of unbound bilirubin, the driver for bilirubin escaping from the vasculature, can be calculated from the TBS and binding capacitl. Presently existing methods for assaying binding capacity and unbound bilirubin are not facile. However, all these parameters can be directly measured simply in a very small volume of whole blood with a special purpose fluorometer, the hematofluorometer, first described years ago, by making use of the natural fluorescence of bilirubin bound to albumin. This technology is amenable to point-of-care use. The aims of this project are to transform the modernized and miniaturized hematofluorometer developed in Phase I into a product suitable for operation in various point-of-care environments, including the intensive care and healthy baby nurseries, the neonatal inpatient clinic, and the pediatrician's office. The first aim is to optimize the basic optical and electronic design: redesin the electronics to support the hospital information management requirements, such as a bar code reader, printer, and interface with a computer, either directly or via the local internet. The second aim is to develop a reagent kit that is easy to use and inexpensive. Phase I work demonstrated that significantly more work is needed to design a kit meeting these requirements, and then scaling this design up into a product that can be mass produced. The third aim is to test the instrument with neonate blood samples in a clinical environment to demonstrate that it well suited to meet the needs. With this goal in mind, Stanford University's Medical School and Children's Hospital has agreed to participate as a subcontractor to evaluate the new technology. With these proposed improvements, the instrument will be ready for the next stages: releasing it to the market for immediate R&D uses and clinical studies, and eventual approval by the FDA for general use.

IC Name
NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING
  • Activity
    R44
  • Administering IC
    EB
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    165920
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    286
  • Ed Inst. Type
  • Funding ICs
    NIBIB:165920\
  • Funding Mechanism
    SBIR-STTR RPGs
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    AVIV BIOMEDICAL, INC.
  • Organization Department
  • Organization DUNS
    148646664
  • Organization City
    LAKEWOOD
  • Organization State
    NJ
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    087016907
  • Organization District
    UNITED STATES