Polyurethane Bone Cements for Total Hip Implants

Information

  • Research Project
  • 7904349
  • ApplicationId
    7904349
  • Core Project Number
    R43AR057614
  • Full Project Number
    1R43AR057614-01A1
  • Serial Number
    57614
  • FOA Number
    PA-09-080
  • Sub Project Id
  • Project Start Date
    6/1/2010 - 14 years ago
  • Project End Date
    10/31/2011 - 13 years ago
  • Program Officer Name
    PANAGIS, JAMES S.
  • Budget Start Date
    6/1/2010 - 14 years ago
  • Budget End Date
    10/31/2011 - 13 years ago
  • Fiscal Year
    2010
  • Support Year
    1
  • Suffix
    A1
  • Award Notice Date
    5/31/2010 - 14 years ago
Organizations

Polyurethane Bone Cements for Total Hip Implants

DESCRIPTION (provided by applicant): Polymethylmethacrylate (PMMA) has been used as a bone cement in total hip arthroplasty (THA) since the 1960's and today is still used in a significant percentage of the 1.5 million THA procedures performed worldwide each year. Despite its long clinical history the orthopaedic community acknowledges shortcomings with PMMA including among other things its exotherm, the toxicity of any unreacted monomer, its encapsulation by fibrous tissue and its cement-implant interface strength [1][2]. This proposal will focus on the later point, the cement-implant (or cement-metal) interface strength. Local debonding at this interface initiates a cascade of events;micromotion, particulate debris generation, macrophage activity, bone resorption and finally aseptic loosening of the implant. Attempts have been made to improve the interface strength of PMMA, but gains have been marginal, leading researchers to conclude that it's not an issue of if the interface should fail but when [3]. The use of polyurethane (PUR) based cement provides a completely different approach to addressing this clinical problem. PURs have a proven record of biostability and biocompatibility going back several decades [4]. More recently, in situ curing PUR adhesive formulations have been introduced to European markets and are seeing clinical use as bone void fillers and in stabilizing fractures. These PUR based cements have been shown to provide strong bond to bone and metal. As clinical experience with these materials grows, there is significant interest in development of PUR bone cement for affixation of total joint replacement devices. This research proposes development of a PUR bone cement specifically engineered for the biomechanical demands of THA. Phase 1 of the project will include formulation of new PURs using fundamental structure- property principles of polymer chemistry to provide a reactive two part system that upon mixing achieves full load bearing properties within 24 hour, strong adhesion to bone and metal implants, and long-term biostability. These formulations will then undergo mechanical testing to gain a full understanding of their capabilities. Of specific interest in Phase 1 will be their adhesion to THA devices and bone. The materials will be subjected to both static and dynamic test protocols, reproducing in vivo loads in a laboratory model. In parallel, the new materials will undergo in vitro biostability testing to characterize the risk of in situ oxidative degradation that would limit its clinical viability. Furthermore, level of extractable monomers will be evaluated for developed PURs and compared to PMMA. The overarching objective of these tests is to assess each material's potential as a replacement for PMMA in THA. Later phases of the project would include further refinement of the leading candidate material to improve load bearing capability, adhesion, and biostability, and to complete biocompatibility testing, mechanical assessment under more complex loading, and ultimately human clinical use. PUBLIC HEALTH RELEVANCE: The overall goal of this project is to develop a polyurethane adhesive bone cement for use in total hip replacement surgery. This alternative to polymethylmethacrylate will have superior bond strength between the cement and the metal device, significantly reducing the risk of failure due to loosening at this interface. The technology developed in this study has the potential to improve the lives of over 1.5 million new patients each year who undergo hip replacement surgeries.

IC Name
NATIONAL INSTITUTE OF ARTHRITIS AND MUSCULOSKELETAL AND SKIN DISEASES
  • Activity
    R43
  • Administering IC
    AR
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    155641
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    846
  • Ed Inst. Type
  • Funding ICs
    NIAMS:155641\
  • Funding Mechanism
    SBIR-STTR
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    TROY POLYMERS, INC.
  • Organization Department
  • Organization DUNS
    022503648
  • Organization City
    TROY
  • Organization State
    MI
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    480851442
  • Organization District
    UNITED STATES