Rapid, noninvasive diagnosis and monitoring of shock

Information

  • Research Project
  • 7912697
  • ApplicationId
    7912697
  • Core Project Number
    R41HL103095
  • Full Project Number
    1R41HL103095-01
  • Serial Number
    103095
  • FOA Number
    PA-09-081
  • Sub Project Id
  • Project Start Date
    8/1/2010 - 14 years ago
  • Project End Date
    6/30/2013 - 11 years ago
  • Program Officer Name
    PUCIE, SUSAN
  • Budget Start Date
    8/1/2010 - 14 years ago
  • Budget End Date
    6/30/2013 - 11 years ago
  • Fiscal Year
    2010
  • Support Year
    1
  • Suffix
  • Award Notice Date
    7/21/2010 - 14 years ago
Organizations

Rapid, noninvasive diagnosis and monitoring of shock

DESCRIPTION (provided by applicant): Assessment and management of circulatory shock in critically ill patients requires rapid measurement of two critical variables: mixed venous oxyhemoglobin saturation (venous SO2) and total blood hemoglobin concentration [Hgb] to identify insufficient oxygen delivery and anemia and to determine the need for therapy with fluids, inotropic or vasodilator drugs or blood transfusion. Current invasive techniques for measurement of venous SO2 and [Hgb] require central venous or pulmonary arterial catheterization and blood sampling. In emergency department patients with septic shock, management based on maintaining venous SO2 at e 70%, as measured invasively in the superior vena cava, reduced mortality from 46.5% to 30.5%. At present, no available noninvasive technique measures venous SO2 and [Hgb] to guide treatment. Our research team has pioneered optoacoustic imaging techniques for accurate, non-invasive, real-time measurement of SO2 and [Hgb]. We designed, built, and performed in vitro and in vivo testing of a novel, compact, high-resolution optoacoustic imaging system that measures SO2 and [Hgb] directly from blood vessels. The optoacoustic imaging is based on generation of ultrasonic (optoacoustic) waves by near infra-red laser light pulses and detection of optoacoustic waves by a sensitive wide-band acoustic transducer. Optoacoustic waves are linearly dependent on SO2 and [Hgb]. Our in vitro and in vivo tests of the system with optoacoustic probes demonstrated that the system is capable of measuring oxygenation and [Hgb] measurement with high accuracy approaching that of the CO-Oximeter, the conventional gold standard method for measuring oxygen saturation in blood. In this application, our multidisciplinary team of bioengineers and intensivists proposes to develop and test novel, highly-portable clinical, prototype with unique capabilities for rapid, noninvasive assessment and management of circulatory shock in surgical and critically ill patients. PUBLIC HEALTH RELEVANCE: The proposed project will have a substantial impact on care of patients undergoing surgery, critically ill patients, and patients in shock. The proposed optoacoustic system will replace invasive, intermittent diagnostic testing of central venous blood oxygenation hemoglobin with noninvasive, rapid, and continuous monitoring.

IC Name
NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
  • Activity
    R41
  • Administering IC
    HL
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    162065
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    837
  • Ed Inst. Type
  • Funding ICs
    NHLBI:162065\
  • Funding Mechanism
    SBIR-STTR
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    NONINVASIX, INC.
  • Organization Department
  • Organization DUNS
    801196960
  • Organization City
    GALVESTON
  • Organization State
    TX
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    775552240
  • Organization District
    UNITED STATES