SBIR Phase I: Engineered Sensors for the Pulmonary Forced Oscillation Technique

Information

  • NSF Award
  • 1248714
Owner
  • Award Id
    1248714
  • Award Effective Date
    1/1/2013 - 11 years ago
  • Award Expiration Date
    6/30/2013 - 11 years ago
  • Award Amount
    $ 149,785.00
  • Award Instrument
    Standard Grant

SBIR Phase I: Engineered Sensors for the Pulmonary Forced Oscillation Technique

This Small Business Innovation Research Phase I project will advance the development of a new pulmonary testing instrument. The innovative device utilizes a strain gauge to measure pulmonary airflow, an indicator critical in monitoring the health of asthma and chronic obstructive pulmonary disease (COPD) patients. The research challenge is to develop and demonstrate the feasibility of a customized strain gauge for this device. This will involve fabricating and testing thin film sensors and comparing their efficacy to the commercial sensor now used. The customized sensors will be developed in a university-based clean room and tested against the commercial sensors by comparing signal to noise measurements. Research efforts will aim at improving signal to noise and minimizing non-linear responses seen in the commercial sensor. For this proposal, the specific application of the new sensor will be in a device that will measure pulmonary airflow resistance using the Forced Oscillation Technique (FOT). <br/><br/>The broader impact/commercial potential of this project will be to market an instrument that has significant advantages over those currently in use to measure lung airflow of pulmonary disease patients. An estimated 36.4 million Americans suffer from asthma or chronic obstructive pulmonary disease (COPD). Successful development of the proposed assistive technology will offer a low-cost, easily cleaned, readily mobile testing device that is adaptable to home use. The specific application proposed for this device, forced oscillation technique (FOT), has a significant advantage over standard spirometry, as it does not depend upon deliberate cooperation of the patient to perform required respiratory maneuvers. It is therefore useful for comatose patients, infants and children, mentally and physically impaired individuals, and even animals. FOT devices are new developments; they are being used primarily in research settings. The device proposed here will be extremely competitive in the marketplace, primarily due to its low cost, but also to its simple design and ease of use. Software developed for his device will make the wireless transfer of data from the patient?s home to the physician?s office effortless.

  • Program Officer
    Muralidharan S. Nair
  • Min Amd Letter Date
    12/6/2012 - 11 years ago
  • Max Amd Letter Date
    12/6/2012 - 11 years ago
  • ARRA Amount

Institutions

  • Name
    Feather Sensors, LLC
  • City
    Millville
  • State
    NJ
  • Country
    United States
  • Address
    1122 North High Street
  • Postal Code
    083322529
  • Phone Number
    9085813166

Investigators

  • First Name
    Charles
  • Last Name
    Forbes
  • Email Address
    ned@feathersensors.com
  • Start Date
    12/6/2012 12:00:00 AM