SELF REGULATING PUMP CHAMBER FOR STANDARD ROLLER PUMP

Information

  • Research Project
  • 3500958
  • ApplicationId
    3500958
  • Core Project Number
    R43HL037168
  • Full Project Number
    1R43HL037168-01A1
  • Serial Number
    37168
  • FOA Number
  • Sub Project Id
  • Project Start Date
    8/1/1987 - 38 years ago
  • Project End Date
    3/31/1988 - 37 years ago
  • Program Officer Name
  • Budget Start Date
    8/1/1987 - 38 years ago
  • Budget End Date
    3/31/1988 - 37 years ago
  • Fiscal Year
    1987
  • Support Year
    1
  • Suffix
    A1
  • Award Notice Date
    7/30/1987 - 38 years ago
Organizations

SELF REGULATING PUMP CHAMBER FOR STANDARD ROLLER PUMP

The roller pump, used to pump blood flow during cardiopulmonary bypass and long term circulatory support, is a constant blood flow device. It maintains constant flow independent of the clinically expected changes in inlet pressures. A decrease in blood supply to the inlet of the pump without a concomitment decrease in pump speed can cause excessive suction leading to air embolism, thrombosis and damage by the "venous" cannula to the vessels's intima or, with a bubble oxygentator, the emptying of the oxygenator and pumping air to the patient. Present safety features are either ON-OFF controls, or it cannot be used without modifying the standard roller pump. It is the purpose of this research to design, fabricate and evaluate a new innovative disposable pump chamber for the standard roller pump that self-controls the pump flow as a function of inlet or filling pressure, much like the natural heart. The pump chamber consists of an easily collapsible thin wall tubing (TWT) housed and sealed in a standard pump tubing. The inner TWT serves to pump blood and the outer tubing serves as a mechanical support and controlled pressure environment for the TWT. This pump chamber can provide additional safety during open heart surgery and a very inexpensive self-controlling mechanism for long term circulatory support.

IC Name
NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
  • Activity
    R43
  • Administering IC
    HL
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    837
  • Ed Inst. Type
  • Funding ICs
  • Funding Mechanism
  • Study Section
    SSS
  • Study Section Name
  • Organization Name
    ADAM SPENCE CORPORATION
  • Organization Department
  • Organization DUNS
  • Organization City
    WALL
  • Organization State
    NJ
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    11030
  • Organization District
    UNITED STATES