Shape Memory Polymer Vascular Occlusion Device for the Treatment of Venous Insufficiency Phase II

Information

  • Research Project
  • 9355638
  • ApplicationId
    9355638
  • Core Project Number
    R44EB022016
  • Full Project Number
    5R44EB022016-03
  • Serial Number
    022016
  • FOA Number
    PA-15-269
  • Sub Project Id
  • Project Start Date
    9/21/2016 - 7 years ago
  • Project End Date
    8/31/2018 - 5 years ago
  • Program Officer Name
    RAMPULLA, DAVID
  • Budget Start Date
    9/1/2017 - 6 years ago
  • Budget End Date
    8/31/2018 - 5 years ago
  • Fiscal Year
    2017
  • Support Year
    03
  • Suffix
  • Award Notice Date
    8/15/2017 - 6 years ago
Organizations

Shape Memory Polymer Vascular Occlusion Device for the Treatment of Venous Insufficiency Phase II

ABSTRACT Venous insufficiency (VI) is the cause of more than 500,000 annual hospitalizations in the U.S. and accounts for more than $1 billion in annual healthcare expenses, accounting for approximately 2% of the entire healthcare budget. VI occurs when the valves within veins are weakened and can no longer prevent backflow and blood pooling. As a result, the vein dilates and if left untreated can cause persistent abdominal pain, infertility, and even ulcer formation. To alleviate the symptoms of VI, physicians aim to permanently exclude the diseased vessel from systemic flow. The current gold standard of treatment is the implantation of platinum embolic coils combined with a detergent injection, known as sclerotherapy, which chemically burns the endothelium of the vessel and causes scar formation within the vein. However, up to 15% of patients experience recanalization, or the restoration of blood flow through a previously treated vessel. This often requires the patient to undergo a second, or even third treatment, to permanently occlude the vein. Treatments can also require the implantation of up to 16 coils, which creates prohibitive device costs for treatment facilities, and increased radiation exposure for the patient. The proposed project outlines the continued development of a shape memory polymer (SMP) foam peripheral embolization device (PED) to treat complications associated with VI. The PED will provide rapid, complete occlusion of the refluxing veins with minimal risk of device dislocation, vessel rupture, and damage to surrounding tissues. The realm of treatable veins with VI will also be extended by the material properties of the PED and the ability to be easily delivered to tortuous vessels. Benchtop device verification studies will be performed to ensure the proposed device has adequate mechanical strength, requires minimal force for advancement through the catheter, and the SMP foam is securely attached to the PED to prevent thromboembolism. The biocompatibility of the PED will also be extensively evaluated through ISO 10993 studies typically performed on this class of devices. Finally, the PED will be delivered to twelve preclinical animals and analyzed for ease of delivery and navigation, device migration, time to occlusion, recanalization at 30 and 90-day follow up, and local and system toxicity. At the culmination of this work, all studies necessary for submission to the FDA for 510(k) clearance will be completed.

IC Name
NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING
  • Activity
    R44
  • Administering IC
    EB
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    1125686
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    286
  • Ed Inst. Type
  • Funding ICs
    NIBIB:1125686\
  • Funding Mechanism
    SBIR-STTR RPGs
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    SHAPE MEMORY MEDICAL INC.
  • Organization Department
  • Organization DUNS
    025984823
  • Organization City
    SANTA CLARA
  • Organization State
    CA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    950542254
  • Organization District
    UNITED STATES