Silicone Coatings for Biostable Chronic Neural Prostheses

Information

  • Research Project
  • 8516117
  • ApplicationId
    8516117
  • Core Project Number
    R44NS060377
  • Full Project Number
    5R44NS060377-04
  • Serial Number
    060377
  • FOA Number
    PA-10-050
  • Sub Project Id
  • Project Start Date
    9/1/2007 - 17 years ago
  • Project End Date
    7/31/2015 - 9 years ago
  • Program Officer Name
    FERTIG, STEPHANIE
  • Budget Start Date
    8/1/2013 - 11 years ago
  • Budget End Date
    7/31/2015 - 9 years ago
  • Fiscal Year
    2013
  • Support Year
    04
  • Suffix
  • Award Notice Date
    7/26/2013 - 11 years ago
Organizations

Silicone Coatings for Biostable Chronic Neural Prostheses

DESCRIPTION (provided by applicant): The miniaturization of neuroprosthetic technology has led to an urgent need for thin, conformal, insulating coatings that retain their biocompatibility and stability over long periods. Silicone coatings have long been used in the medical device industry for their biocompatibility and electrically insulating properties. However, conventional silicone encapsulation technologies are unfit for many miniature medical devices including implantable, chronic microelectrode arrays used in some neuroprosheses. Initiated Chemical Vapor Deposition (iCVD) is an attractive alternative to conventional polymer coatings applied using solvent-based techniques such as dip/spray and curing. iCVD has the benefits of thinness, conformality (conforms very well to complex shapes) and high purity. The goal of this work is to produce electrically insulating, biostable iCVD coatings for chronic neural prosthetic devices. In Phase I, we have demonstrated that iCVD silicone coatings exhibit prolonged stability in simulated in-vivo environments under constant sweeping voltage bias (6+ years under soak without any loss in resistivity), show excellent adhesion and flexibility, are bioinert, and meet USP Plastic Class VI requirements. Furthermore, we have demonstrated a three folds increase in deposition rate via the codeposition of a linear siloxane spacer molecule, making the process even more economically viable for commercialization. In Phase II, GVD will qualify promising deposition conditions and de-insulation methods for neural probe coatings. A serives of in-vitro tests will allow us to downselect the most promising conditions. GVD will partner with Dr. William Shain (Seattle Children's Research Institute) to confirm the suitability of selected probe coating methods through staggered in vivo studies. Upon successful performance demonstrated during the in vivo studies, GVD will design an upgraded coating system optimized for cost-effective commercial production of successful coatings. The ultimate goal of this work is to achieve single step encapsulation of three-dimensional neural probe arrays and of neural prosthetic assemblies. The development of a stable, durable, biocompatible insulating coating under this Phase II will enable that goal to be achieved.

IC Name
NATIONAL INSTITUTE OF NEUROLOGICAL DISORDERS AND STROKE
  • Activity
    R44
  • Administering IC
    NS
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    523986
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    853
  • Ed Inst. Type
  • Funding ICs
    NINDS:523986\
  • Funding Mechanism
    SBIR-STTR RPGs
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    GVD CORPORATION
  • Organization Department
  • Organization DUNS
    085502958
  • Organization City
    CAMBRIDGE
  • Organization State
    MA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    021381046
  • Organization District
    UNITED STATES