Simultaneous SPECT/CT with a single photon counting camera

Information

  • Research Project
  • 8200367
  • ApplicationId
    8200367
  • Core Project Number
    R43EB012890
  • Full Project Number
    1R43EB012890-01A1
  • Serial Number
    12890
  • FOA Number
    PA-10-050
  • Sub Project Id
  • Project Start Date
    7/15/2011 - 13 years ago
  • Project End Date
    11/30/2012 - 12 years ago
  • Program Officer Name
    SASTRE, ANTONIO
  • Budget Start Date
    7/15/2011 - 13 years ago
  • Budget End Date
    11/30/2012 - 12 years ago
  • Fiscal Year
    2011
  • Support Year
    1
  • Suffix
    A1
  • Award Notice Date
    7/7/2011 - 13 years ago
Organizations

Simultaneous SPECT/CT with a single photon counting camera

DESCRIPTION (provided by applicant): This Phase I grant titled, "Simultaneous SPECT/CT with a single photon counting camera" will enable the development of a fast photon-counting x-ray and gamma-ray imaging array with energy discrimination. The aims of the project when completed will demonstrate several advances in the technologies used to fabricate vertically integrated dense arrays. Recently, new technological developments in connecting sensors to the reduced size of application specific integrated circuits (ASICs) has been applied to reading out semiconductor detectors These advances, along with improvements to the cost and reliability of the compound semiconductor cadmium telluride (CdTe), allow us to develop a photon counting detector and read-out technology for higher spatial resolution single photon emission computed tomography (SPECT) and energy resolved single photon counting x-ray computed tomography (CT) at reduced dose. These detectors improve spatial resolution in SPECT imaging with direct conversion CdTe sensors and 0.5 mm pixels which are three times smaller than currently available commercially. These same detectors, which maintain good energy resolution up to 5 W 106 counts per second per pixel (the world's fastest output count rate), enable significant improvements in CT imaging such as reduced patient dose while maintaining excellent image quality, enhanced tissue contrast, and material decomposition capabilities (tissue type identification). Photon counting detectors with energy binning can improve CT performance by counting and binning each x-ray detected. Additionally, the simultaneous acquisition of anatomical and functional data from identical image volumes will reduce coregistration errors which will be extremely important for the accurate anatomical localization of uptake on sub- millimeter length scales. This project produces several important technological innovations. These include the fabrication of single crystal CdTe detectors with an active area extending to the edge of the crystals (no guard rings) which allows tiling with almost no dead space. Additionally, we have developed packaging and encapsulation methods to connect dense multi channel fast application specific integrated circuits (ASICs) to the crystals and formed within the active area of the crystal to preserve tiling in two dimensions. And we achieve a rapid signal formation, shorter than the transit time for charge carriers across the CdTe crystal. In this Phase I project we will demonstrate a vertically integrated photon counting SPECT and CT detector with energy binning and read-out that is capable of producing higher spatial resolution SPECT and energy resolved CT which can deliver less radiation dose and differentiate between tissue types. Achieving vertical integration while maintaining performance will allow the tiling of Phase I modules in Phase II to larger fields of view. The innovative methods described in this proposal could have a tremendous significance by developing methods that improve SPECT and CT imaging and could one day be translated to the clinic. There remains however a large risk in the final integration of the vertical readout ASICs to the CdTe detectors. As we are developing the world's fastest x-ray and gamma-ray detector arrays by using the latest and smallest bonding techniques available, this is not a low risk step in the development. Completion of the Phase I milestones in a vertically integrated array will successfully address this risk as well as demonstrate significantly improved performance as compared to the currently available SPECT and CT detectors. PUBLIC HEALTH RELEVANCE: We are developing fast photon counting arrays for x-ray and gamma-ray imaging. This new detector technology can potentially reduce dose and improve contrast when applied to x-ray CT. Additionally, the detector can perform simultaneous SPECT and CT. The proposal submitted contains several innovative advancements to the current state of the art technologies employed in both CT and SPECT.

IC Name
NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING
  • Activity
    R43
  • Administering IC
    EB
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    150574
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    286
  • Ed Inst. Type
  • Funding ICs
    NIBIB:150574\
  • Funding Mechanism
    SBIR-STTR
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    DXRAY, INC.
  • Organization Department
  • Organization DUNS
    153098871
  • Organization City
    NORTHRIDGE
  • Organization State
    CA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    913243577
  • Organization District
    UNITED STATES