Single-use, disposable PCR home self-testing device to detect HIV-1 RNA in finger-stick blood

Information

  • Research Project
  • 9609330
  • ApplicationId
    9609330
  • Core Project Number
    R61AI140468
  • Full Project Number
    1R61AI140468-01
  • Serial Number
    140468
  • FOA Number
    PAR-17-471
  • Sub Project Id
  • Project Start Date
    8/1/2018 - 6 years ago
  • Project End Date
    7/31/2021 - 3 years ago
  • Program Officer Name
    FITZGIBBON, JOSEPH E
  • Budget Start Date
    8/1/2018 - 6 years ago
  • Budget End Date
    7/31/2019 - 6 years ago
  • Fiscal Year
    2018
  • Support Year
    01
  • Suffix
  • Award Notice Date
    8/1/2018 - 6 years ago
Organizations

Single-use, disposable PCR home self-testing device to detect HIV-1 RNA in finger-stick blood

1 The proposed project will demonstrate proof-of-concept that a single-use, disposable nucleic acid amplification 2 device suitable for home self-testing can automatically and rapidly amplify and detect HIV-1 genomic RNA from 3 a finger-stick blood sample. The device will extract nucleic acid from plasma or whole blood, amplify HIV-1 4 RNA, and detect amplified product, providing sample to answer in < 30 minutes. The device will be simple and 5 easy to use, and therefore suitable as a home self-test. This proposed development is based on Click 6 Diagnostics? single-use, disposable PCR diagnostic device that will enter an NIH-funded clinical trial in 2018 for 7 the rapid detection of three sexually transmitted infections, N. gonorrhoeae, C. trachomatis, and T. vaginalis, 8 using self-collected vaginal swabs. The R61 phase of the project will develop and port a multiplex RT-PCR 9 HIV-1 assay onto Click Diagnostics? platform, and will qualitatively assess the presence of HIV-1 Group O and 10 Group M (subtype A-H) RNA at concentrations as low as 1000 copies/ml. As plasma represents the gold- 11 standard sample matrix for accurately detecting HIV RNA, we partnered with two companies to evaluate their 12 non-centrifugation based methods to separate plasma from finger-stick blood; these include a 13 superhydrophobic surface/membrane filtration system and a size-selection membrane filter system. Finally, we 14 will evaluate the possibility of direct amplification of HIV-1 RNA from whole finger-stick blood. This method will 15 not require plasma separation, and will selectively amplify only HIV-1 RNA (but not pro-viral DNA) from an 16 EDTA anticoagulated blood sample. Based on performance, one of these methods will be chosen for use with 17 the Click diagnostic test, and for potential future physical integration into the Click device. The R33 phase of 18 the project will focus on evaluation and optimization of HIV diagnostic using archived de-identified plasma 19 samples from HIV-1 infected patients representing a range of viral loads and HIV-1 Group O and Group M 20 subtypes. Click Diagnostics has partnered with the Department of Veterans Affairs, Palo Alto AIDS Research 21 Center to assist with device evaluation and testing. The testing will demonstrate that the integrated device can 22 detect HIV-1 RNA from patient de-identified plasma samples in the HIV-1 Early Infection AccuSet Performance 23 Panel spiked into EDTA anticoagulated whole blood. Limit of Detection (LoD) and inclusivity/exclusivity results 24 will be compared with, and are expected to be comparable to, commercially available comparator instrument- 25 based PCR assays. At the conclusion of proposed project, the device will be ready for: 1) physical integration 26 of plasma separation with the Click device; 2) a pre-submission meeting with the FDA prior to conducting 27 formal pre-analytical and pre-clinical studies; 3) a user study to determine the feasibility of the device for home 28 self-testing; and 4) a manufacturing readiness assessment preceding volume production of sufficient devices 29 for a pivotal clinical trial. The fully integrated Click HIV diagnostic will bring accurate and easy to use HIV RNA 30 self-testing devices into the home, thus markedly increasing access, while decreasing costs.

IC Name
NATIONAL INSTITUTE OF ALLERGY AND INFECTIOUS DISEASES
  • Activity
    R61
  • Administering IC
    AI
  • Application Type
    1
  • Direct Cost Amount
    300000
  • Indirect Cost Amount
    104129
  • Total Cost
    404129
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    855
  • Ed Inst. Type
  • Funding ICs
    NIAID:404129\
  • Funding Mechanism
    Non-SBIR/STTR RPGs
  • Study Section
    ZAI1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    CLICK DIAGNOSTICS, INC.
  • Organization Department
  • Organization DUNS
    933894748
  • Organization City
    San Jose
  • Organization State
    CA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    95134
  • Organization District
    UNITED STATES