Small Field of View Solid-State Gamma Camera Development

Information

  • Research Project
  • 6401757
  • ApplicationId
    6401757
  • Core Project Number
    R43CA092859
  • Full Project Number
    1R43CA092859-01
  • Serial Number
    92859
  • FOA Number
  • Sub Project Id
  • Project Start Date
    8/1/2001 - 25 years ago
  • Project End Date
    4/30/2003 - 23 years ago
  • Program Officer Name
    CHEUNG, GEOFFREY P.
  • Budget Start Date
    8/1/2001 - 25 years ago
  • Budget End Date
    4/30/2003 - 23 years ago
  • Fiscal Year
    2001
  • Support Year
    1
  • Suffix
  • Award Notice Date
    8/1/2001 - 25 years ago
Organizations

Small Field of View Solid-State Gamma Camera Development

We propose to develop a commercially viable very small field of view (VSFOV) solid-state gamma camera. The intended use is to provide intro-operative imaging in sentinel lymph node biopsy procedures for staging breast cancer and melanoma. The camera will enhance the data available to the surgeon by providing an image of a 2cm x 2cm area as compared to the single-detector probes in general use today. The core imaging detectors which will be incorporated into the proposed device are currently under development at Lawrence Berkeley National Labs and Capintec under a CRADA. Successful prototypes of several core detectors have been developed previously, but not used in a camera. Development of production core detectors will be completed in the first half of 2001, making them available for use in the VSFOV camera. The proposed camera, data acquisition electronics and dedicated readout are outside the scope of the CRADA. The solid-state VSFOV camera is a potentially powerful tool, surpassing currently available-technology. Not reliant on large photomultiplier tubes, it will be light enough to be hand-held and thin enough to position in anatomically difficult areas. It can be applied directly to the region of interest, improving efficiency and decreasing imaging time. PROPOSED COMMERCIAL APPLICATIONS: Biopsy of the first tumor-draining lymph node, the sentinel lymph node has become the standard of care in staging breast cancer and melanoma--the market is established and growing rapidly. These biopsy procedures rely on single-detector probes to identify radioactive nodes. The proposed device will offer the surgeon imaging data previously unavailable during the procedure, which we expect will improve the effectiveness and efficiency of the procedure.

IC Name
NATIONAL CANCER INSTITUTE
  • Activity
    R43
  • Administering IC
    CA
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    129442
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    395
  • Ed Inst. Type
  • Funding ICs
    NCI:129442\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    CAPINTEC, INC.
  • Organization Department
  • Organization DUNS
  • Organization City
    RAMSEY
  • Organization State
    NJ
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    07446
  • Organization District
    UNITED STATES