Solid State Gamma Ray Imaging Detectors, Novel Packaging

Information

  • Research Project
  • 6549209
  • ApplicationId
    6549209
  • Core Project Number
    R43RR016822
  • Full Project Number
    1R43RR016822-01A1
  • Serial Number
    16822
  • FOA Number
  • Sub Project Id
  • Project Start Date
    12/1/2002 - 22 years ago
  • Project End Date
    11/30/2003 - 21 years ago
  • Program Officer Name
    SWAIN, AMY L
  • Budget Start Date
    12/1/2002 - 22 years ago
  • Budget End Date
    11/30/2003 - 21 years ago
  • Fiscal Year
    2003
  • Support Year
    1
  • Suffix
    A1
  • Award Notice Date
    -

Solid State Gamma Ray Imaging Detectors, Novel Packaging

[unreadable] DESCRIPTION (provided by applicant): Proposed is advancement of the state-of-the-art for pixilated Cadmium Zinc Telluride (CZT) gamma ray imaging array detector assemblies to where their advantages of energy and spatial resolution in a room temperature detector may be exploited with minimal cost and risk in applications such as large area arrays for in vivo imaging and nuclear medicine. [unreadable] [unreadable] More specifically, the aim is to produce detector arrays for the imaging research community by applying to CZT-ASIC readout assemblies recently-developed techniques for packaging and production of flip chips. The approach involves special metallizations and encapsulation of the devices prior to assembly, as well as low-temperature bump soldering techniques. These will be used to inexpensively reproduce, in quantity, multiple CZT-gamma ray detector arrays which were developed at the University of Arizona. Particular emphasis will be placed on those technological aspects that relate to processing of the detector materials for manufacturing in large quantity at low cost. The new techniques will be implemented with the aim of scaling up to large-scale production. [unreadable] [unreadable] The immediate commercial opportunity is in supplying the research community a reliable supply of functional imaging array detector assemblies. These devices have applications in planar imaging, SPECT imaging systems, and as surgical probes. Some possible applications are mammography, clinical cardiology, in vivo auto radiography, neuroscience studies, and lymphatic system imaging. There exists a huge potential for in vivo gene expression studies in small animals. Outside of medial and biological uses, detector arrays are needed by NASA for stellar X-and gamma ray imaging systems.

IC Name
NATIONAL CENTER FOR RESEARCH RESOURCES
  • Activity
    R43
  • Administering IC
    RR
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    100000
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    371
  • Ed Inst. Type
  • Funding ICs
    NCRR:100000\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    AGUILA TECHNOLOGIES, INC.
  • Organization Department
  • Organization DUNS
    957992522
  • Organization City
    SAN MARCOS
  • Organization State
    CA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    920782631
  • Organization District
    UNITED STATES