SOURCE WIRES FOR ACUTE ENDOVASCULAR RADIOTHERAPY

Information

  • Research Project
  • 6142006
  • ApplicationId
    6142006
  • Core Project Number
    R43CA086605
  • Full Project Number
    1R43CA086605-01
  • Serial Number
    86605
  • FOA Number
  • Sub Project Id
  • Project Start Date
    8/18/2000 - 24 years ago
  • Project End Date
    7/31/2001 - 23 years ago
  • Program Officer Name
    STONE, HELEN B.
  • Budget Start Date
    8/18/2000 - 24 years ago
  • Budget End Date
    7/31/2001 - 23 years ago
  • Fiscal Year
    2000
  • Support Year
    1
  • Suffix
  • Award Notice Date
    8/18/2000 - 24 years ago

SOURCE WIRES FOR ACUTE ENDOVASCULAR RADIOTHERAPY

Restenosis, post-operative reclosure of the artery, affects approximately 30% of stent recipients subjected to dilatation of coronary blockages. Clinical exposure of the affected site to a very high dose from a radioactive source mounted at the tip of a catheter results in a significant reduction of restenosis rates. High energy gamma radiation from the current isotope of choice, Iridium-192, is, however, a safety concern for both the patient and personnel administering treatment. While substituting beta emitters for iridium reduces the risk of exposure to staff, energy deposited in tissue by beta rays diminishes rapidly with distance from the source, and is virtually extinguished in approximately 2 mm, making treatment of vascular walls difficult. Implant Sciences proposes to improve the safety of wire sources by pairing high-intensity, low-energy x- and gamma-ray emitting isotopes, specifically Iodine-125 and Ytterbium-169. Radiation from both penetrates tissue homogeneously and can be effectively used in treating cellular proliferation beginning in the media and extending to the adventitia. At the same time, unwanted exposure to nearby structures is greatly reduced, as is exposure to persons present in the operating room. PROPOSED COMMERCIAL APPLICATION: This effort is expected to show that iodine-125 and/or ytterbium-169 wire sources are, at the same time, both safe to use and effective restenosis inhibitors. Assuming this result, Implant Sciences Corporation will extend its iodine-125 brachytherapy seed production facilities to include the capacity for fabricating one or both of the proposed wire sources.

IC Name
NATIONAL CANCER INSTITUTE
  • Activity
    R43
  • Administering IC
    CA
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    94843
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    395
  • Ed Inst. Type
  • Funding ICs
    NCI:94843\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    IMPLANT SCIENCES CORPORATION
  • Organization Department
  • Organization DUNS
  • Organization City
    WAKEFIELD
  • Organization State
    MA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    01880
  • Organization District
    UNITED STATES