Stabilization Device for Transseptal Access

Information

  • Research Project
  • 8591527
  • ApplicationId
    8591527
  • Core Project Number
    R43HL117501
  • Full Project Number
    1R43HL117501-01A1
  • Serial Number
    117501
  • FOA Number
    PA-12-088
  • Sub Project Id
  • Project Start Date
    9/1/2013 - 11 years ago
  • Project End Date
    2/28/2015 - 10 years ago
  • Program Officer Name
    LEE, ALBERT
  • Budget Start Date
    9/1/2013 - 11 years ago
  • Budget End Date
    2/28/2015 - 10 years ago
  • Fiscal Year
    2013
  • Support Year
    01
  • Suffix
    A1
  • Award Notice Date
    8/19/2013 - 11 years ago
Organizations

Stabilization Device for Transseptal Access

DESCRIPTION (provided by applicant): Transseptal (TS) access for left heart procedures is an important and rapidly growing space for diagnostics and therapy delivery with an expected total of over 10 million U.S. patients. In the U.S. and/or Europe, TS access procedures are used for atrial fibrillation (AF) ablation, left atrial appendage (LAA) closure, patent foramen ovale (PFO) closure, and treatment of mitral valve regurgitation (MR). For the latter, treatment of severe MR can be accomplished through TS access and the placement of a clip (MitraClip or MC) on the mitral valve. Catheter positioning for MC placement has been challenging even for the most experienced interventionalist cardiologists (ICs) and has led to long procedure times with significant x-ray exposure. The initial TS access entry point into the left side of the heart s the key factor for MC placement. TS access procedures have not significantly changed since early reports by Ross in 1959 (drag and drop technique) and many challenges still exist with this method including difficulty with: catheter localization, catheter stabilization, and the risk f atrial wall or aortic puncture. While the drag and drop technique provides an optimal inferior septal access point for ablation procedures, the MC procedure requires a more superior/posterior puncture site due to the multiple turns required by the catheter for final clip placement. While this superior/posterior position can be located with echocardiography, the constant movement of the heart and the thin and slippery nature of the fossa ovalis (FO) make standard TS access punctures unpredictable. Access that is too high or too low relative to the mitral valve can make implantation of the MC virtually impossible thus requiring device removal, TS re-puncture, and device re-advancement. Thus, initial localization on the FO with subsequent stabilization prior to and during TS access is critical for MC procedures to limit implant times and x-ray exposure. In this proposal, we will validate the ability of a novel, deflectable transseptal access catheter (TSAC) that utilizes vacuum suction technology to provide improved catheter localization and stabilization, easier puncture of the FO, and thus leading to decreased TS and MC procedural and x-ray exposure times. To accomplish this goal, we will assess both the safety and the ability of the TSAC to reduce procedure and x-ray exposure times for delivery of MC relative to traditional means for TS access in human cadavers with heart failure and in chronic heart failure swine with MR. This proposal addresses a clinically significant problem with applications that can reach beyond treatment of MR to multiple TS left heart procedures.

IC Name
NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
  • Activity
    R43
  • Administering IC
    HL
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    269255
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    837
  • Ed Inst. Type
  • Funding ICs
    NHLBI:269255\
  • Funding Mechanism
    SBIR-STTR RPGs
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    3DT HOLDINGS, LLC
  • Organization Department
  • Organization DUNS
    804419740
  • Organization City
    SAN DIEGO
  • Organization State
    CA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    921211206
  • Organization District
    UNITED STATES