THERMOACOUSTIC CT OF THE BREAST

Information

  • Research Project
  • 6376112
  • ApplicationId
    6376112
  • Core Project Number
    R01CA065744
  • Full Project Number
    7R01CA065744-05
  • Serial Number
    65744
  • FOA Number
  • Sub Project Id
  • Project Start Date
    5/3/1996 - 29 years ago
  • Project End Date
    4/30/2003 - 22 years ago
  • Program Officer Name
  • Budget Start Date
    5/1/2001 - 24 years ago
  • Budget End Date
    4/30/2002 - 23 years ago
  • Fiscal Year
    2001
  • Support Year
    5
  • Suffix
  • Award Notice Date
    5/14/2001 - 24 years ago
Organizations

THERMOACOUSTIC CT OF THE BREAST

DESCRIPTION (Adapted from Applicant's Abstract): During the previous funding period, reported having developed a new medical imaging paradigm called thermoacoustic CT (TCT). In its current implementation, TCT utilizes brief pulses of radio waves at 434 MHz to stimulate acoustic emissions in soft tissue. These sonic emissions are detected by an array of piezo-electric crystals and are recorded temporally following each of 250,000 individual RF pulses. From the recorded sonic emissions, patterns of radio-wave absorption within the soft tissue volume are reconstructed in three dimensions. The applicants reported having demonstrated good soft tissue differentiation in an excised porcine kidney, and we have successfully imaged breast cancer in vivo. The goal of the proposed research program is to better understand the underlying RF-absorption properties of soft tissue, and to improve the current TCT instrumentation for imaging the human breast. To these ends, the following specific aims will be pursued during the proposed three-year funding period: 1. Relate the properties of specific heart, volume thermal expansion and complex permittivity to TCT image contrast: 2. Relate bound water fraction to TCT image contrast; 3. Correlate the physiologic properties of different breast tumor cell lines with TCT image contrast; 4. Develop simulation tools to predict and validate TCT imaging performance in the breast; 5. Design, construct and test an improved TCT breast scanner; and 6. Perform retrospective TCT imaging on small groups of patients

IC Name
NATIONAL CANCER INSTITUTE
  • Activity
    R01
  • Administering IC
    CA
  • Application Type
    7
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    698692
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    394
  • Ed Inst. Type
  • Funding ICs
    NCI:698692\
  • Funding Mechanism
  • Study Section
    DMG
  • Study Section Name
    Diagnostic Imaging Study Section
  • Organization Name
    OPTOSONICS, INC.
  • Organization Department
  • Organization DUNS
    929665875
  • Organization City
    ORIENTAL
  • Organization State
    NC
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    28571
  • Organization District
    UNITED STATES