TWO-DIMENSIONAL, FOCUSED, X-RAY ANTI SCATTER GRIDS

Information

  • Research Project
  • 6513346
  • ApplicationId
    6513346
  • Core Project Number
    R44CA076752
  • Full Project Number
    5R44CA076752-04
  • Serial Number
    76752
  • FOA Number
  • Sub Project Id
  • Project Start Date
    9/30/1997 - 27 years ago
  • Project End Date
    3/31/2004 - 21 years ago
  • Program Officer Name
    CHEUNG, GEOFFREY P.
  • Budget Start Date
    4/1/2002 - 23 years ago
  • Budget End Date
    3/31/2004 - 21 years ago
  • Fiscal Year
    2002
  • Support Year
    4
  • Suffix
  • Award Notice Date
    3/13/2002 - 23 years ago
Organizations

TWO-DIMENSIONAL, FOCUSED, X-RAY ANTI SCATTER GRIDS

Creatv MicroTech proposes to develop high precision, x-ray anti-scatter grids for mammography, which will improve image contrast and signal-to- noise ratio. This is achieved by reducing the scattered x-rays produced by the imaging object. Some of the potential properties of the proposed anti- scatter grid are: (i) the grid pattern is two-dimensional, (ii) the air-core opening is focused to a point x-ray source, (iii) the grid patterns can be made precisely, (iv) the grid patterns are reproducible with precision, and (v) the grid height is unrestricted by fabrication. In Phase I, we demonstrated precise fabrication of unfocused grids up to a grid ratio height of 2.2 mm. A 1.78 mm high two-dimensional nickel grid provided experimentally measured primary transmission of 85% and better reduction of scattered radiation than a 1.5 mm high commercial CGR mammographic grid. For Phase II, we propose to develop the fabrication technology to demonstrate two-dimensional, focused anti-scatter grid of the standard mammographic, anti-scatter grid size. PROPOSED COMMERCIAL APPLICATION: The worldwide market for mammographic units is estimated to be over 1000 by the year 2000. With a benchmark price for an anti-scatter grid of $12K per unit, the market for anti-scatter grids for mammography alone can be as large as $12 million per year by the year 2000. The market for anti-scatter grids for all other medical radiographies and fluoroscopies is estimated to be much larger. In addition, anti-scatter grids are also applicable to non-destructive testing, laboratory research, etc.

IC Name
NATIONAL CANCER INSTITUTE
  • Activity
    R44
  • Administering IC
    CA
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    232725
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    394
  • Ed Inst. Type
  • Funding ICs
    NCI:232725\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    CREATV MICROTECH, INC.
  • Organization Department
  • Organization DUNS
  • Organization City
    POTOMAC
  • Organization State
    MD
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    20854
  • Organization District
    UNITED STATES