TWO MILLIMETER PET SCINTILLATION DETECTOR ARRAY

Information

  • Research Project
  • 3505322
  • ApplicationId
    3505322
  • Core Project Number
    R43RR007535
  • Full Project Number
    1R43RR007535-01
  • Serial Number
    7535
  • FOA Number
  • Sub Project Id
  • Project Start Date
    9/30/1991 - 32 years ago
  • Project End Date
    11/29/1992 - 31 years ago
  • Program Officer Name
  • Budget Start Date
    9/30/1991 - 32 years ago
  • Budget End Date
    11/29/1992 - 31 years ago
  • Fiscal Year
    1991
  • Support Year
    1
  • Suffix
  • Award Notice Date
    9/26/1991 - 32 years ago
Organizations

TWO MILLIMETER PET SCINTILLATION DETECTOR ARRAY

The research proposed in this Phase I grant application will lead to the development of a very high-resolution scintillation detector array for positron emission tomography (PET) imaging. Two alternative schemes will be investigated to improve the image resolution and quantitative accuracy of PET. The first will be an advance to the current "block" detector concept based on an 8x8 array of Bismuth Germanate (BGO), or Lead Sulfate (PbSO4) scintillation crystals coupled through a light guide to four photomultiplier tubes. The crystals will be spaced 3mm apart both axially and transaxially and should provide resolution of approximately 2.5mm in all directions. The second detector configuration will use similar sized array of scintillators but coupled to a grid of silicon photodiodes to determine the interaction detector, with a single large PMT to provide the timing signals. Prototype detectors will be cut from solid blocks of scintillator and tested for the photoelectron yield and event positioning characteristics. The light guide will be adjusted to provide maximum differentiation in the positioning signals between the various crystals of the array while maintaining high light output. Once the lightguide designs have been determined, more detailed measurements will be performed to characterize the positioning accuracy, time resolution, energy resolution, and efficiency. This research should produce the highest resolution PET modular detector design based on four photomultipliers.

IC Name
NATIONAL CENTER FOR RESEARCH RESOURCES
  • Activity
    R43
  • Administering IC
    RR
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    371
  • Ed Inst. Type
  • Funding ICs
  • Funding Mechanism
  • Study Section
    SSS
  • Study Section Name
  • Organization Name
    CTI, INC.
  • Organization Department
  • Organization DUNS
  • Organization City
    KNOXVILLE
  • Organization State
    TN
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    37922
  • Organization District
    UNITED STATES