ULTRASOUND REFLECTION TOMOGRAPHIC BREAST SCANNER

Information

  • Research Project
  • 6376767
  • ApplicationId
    6376767
  • Core Project Number
    R44CA077981
  • Full Project Number
    5R44CA077981-03
  • Serial Number
    77981
  • FOA Number
  • Sub Project Id
  • Project Start Date
    11/1/1998 - 26 years ago
  • Project End Date
    7/31/2003 - 21 years ago
  • Program Officer Name
  • Budget Start Date
    8/7/2001 - 23 years ago
  • Budget End Date
    7/31/2003 - 21 years ago
  • Fiscal Year
    2001
  • Support Year
    3
  • Suffix
  • Award Notice Date
    8/7/2001 - 23 years ago
Organizations

ULTRASOUND REFLECTION TOMOGRAPHIC BREAST SCANNER

Mammography is currently the screening device for breast examination, even though its false-positive rate may be 66% or higher. Thus ultrasound imaging and biopsy must often be used for final diagnosis. However, ultrasound has the potential for improved spatial resolution can provide additional features (currently not available in mammography) to aid in cancer diagnosis such as characterization of the mechanical properties of tissue, 3-D imaging, no ionizing radiation, real-time viewing and improved patient comfort. We intend to demonstrate these advantages with a clinical prototype scanner. TechniScan will design, build and test an advanced clinical prototype ultrasound scanner which will be operator independent, have 3-D capabilities, feature the highest reflection resolution for a given element bandwidth, use multistatic excitation for maximal contrast resolution and perhaps most significantly feature 2 wavelength (0.6 mm at 5 MHz) quantitative images of speed of sound and attenuation. This clinical prototype scanner is expected to demonstrate the advantages of high resolution 3-D ultrasound reflectivity and inverse scattering images to such a high degree that TechniScan can readily develop the funding to produce commercial scanners. PROPOSED COMMERCIAL APPLICATIONS: This proposal will lead to a significant advancement in noninvasive breast cancer screening with non-ionizing ultrasound. It is expected to provide a scanner with higher sensitivity (more suitable to cancer screening) and with lower false positivities (fewer biopsies) and be a strong competitor in a potential billion dollar cancer screening market.

IC Name
NATIONAL CANCER INSTITUTE
  • Activity
    R44
  • Administering IC
    CA
  • Application Type
    5
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    275598
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    394
  • Ed Inst. Type
  • Funding ICs
    NCI:275598\
  • Funding Mechanism
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    TECHNISCAN, INC.
  • Organization Department
  • Organization DUNS
  • Organization City
    SALT LAKE CITY
  • Organization State
    UT
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    84106
  • Organization District
    UNITED STATES