ULTRASOUND REFLECTION TOMOGRAPHIC BREAST SCANNER

Information

  • Research Project
  • 2644076
  • ApplicationId
    2644076
  • Core Project Number
    R43CA077981
  • Full Project Number
    1R43CA077981-01
  • Serial Number
    77981
  • FOA Number
  • Sub Project Id
  • Project Start Date
    8/4/1998 - 27 years ago
  • Project End Date
    8/3/1999 - 26 years ago
  • Program Officer Name
    TORRES-ANJEL, MANUEL J.
  • Budget Start Date
    8/4/1998 - 27 years ago
  • Budget End Date
    8/3/1999 - 26 years ago
  • Fiscal Year
    1998
  • Support Year
    1
  • Suffix
  • Award Notice Date
    8/3/1998 - 27 years ago
Organizations

ULTRASOUND REFLECTION TOMOGRAPHIC BREAST SCANNER

Mammography currently is the screening device for breast examination, although the false-positive rate in it could be 66% or higher. Thus imaging ultrasound and biopsy must often be used for final diagnosis. However, ultrasound has potential for improved spatial resolution, and could provide features that mammography currently does not have: real- time viewing, 3-D imaging, absence of ionizing radiation, and characterization of mechanical properties of the tissue, which we propose to exploit with an advanced ultrasound scanner design. We propose the development of a new technology that will yield an operator-independent, very high-resolution, real-time imager with 3-D imaging capabilities. Our approach is to use a Phase I grant to determine the trade-offs in various methods for applying low F-number 1.5-D arrays with center frequencies of 5 MHz (or higher). Our methods will include B-scan, synthetic focusing with and without corrections for time of flight, and adaptive focusing using a maximum brightness method. The Phase I project will use an existing laboratory scanner to develop the trade-offs for the various methods for the construction of a clinical prototype scanner in Phase II. PROPOSED COMMERCIAL APPLICATIONS: This proposal will lead to a significant advancement in noninvasive breast cancer screening with non-ionizing ultrasound. It is expected to provide a scanner with higher sensitivity (more suitable to cancer screening) and with lower false positivities (fewer biopsies) and be a strong competitor in a potential billion dollar cancer screening market.

IC Name
NATIONAL CANCER INSTITUTE
  • Activity
    R43
  • Administering IC
    CA
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    394
  • Ed Inst. Type
  • Funding ICs
  • Funding Mechanism
  • Study Section
    ZRG7
  • Study Section Name
  • Organization Name
    TECHNISCAN, INC.
  • Organization Department
  • Organization DUNS
  • Organization City
    SALT LAKE CITY
  • Organization State
    UT
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    84106
  • Organization District
    UNITED STATES