Variable Field-of-View Array Body Coil for High Field MR

Information

  • Research Project
  • 6783841
  • ApplicationId
    6783841
  • Core Project Number
    R43EB004299
  • Full Project Number
    1R43EB004299-01
  • Serial Number
    4299
  • FOA Number
    PAR-03-125
  • Sub Project Id
  • Project Start Date
    8/1/2004 - 20 years ago
  • Project End Date
    7/31/2005 - 19 years ago
  • Program Officer Name
    TORRES-ANJEL, MANUEL J.
  • Budget Start Date
    8/1/2004 - 20 years ago
  • Budget End Date
    7/31/2005 - 19 years ago
  • Fiscal Year
    2004
  • Support Year
    1
  • Suffix
  • Award Notice Date
    7/15/2004 - 20 years ago
Organizations

Variable Field-of-View Array Body Coil for High Field MR

[unreadable] DESCRIPTION (provided by applicant): [unreadable] The objective of this project is the development of an improved spin excitation system for MRI imaging. The system is intended to replace the body coil in the next generation of 3T clinical scanners and in future high-field models. The proposed system, a Variable Field of view Array body coil (VFA), is designed to facilitate high resolution neurological or cardiac scanning, as well as large field of view acquisition for major organ systems such as the liver. The VFA will overcome current protocol limitations due to Specific Absorption Rate (SAR) constraints. The VFA will also provide better excitation uniformity for distinguishing fat and other molecular shifts, and deliver more economical power efficiency. [unreadable] [unreadable] The VFA body coil, to be developed, employs a set of short volume coil assemblies arranged on the axis of the scanner. Like recent "dual" gradient designs, the individual coils will have specific spatial sensitivity. By driving the assemblies with separate amplifiers, the assemblies become a phased array capable of a continuously variable excitation profile. The profile can be narrowed for high intensity, and therefore high spatial and temporal scan resolution. Or, the profile can be broadened tbr coverage of large organ systems. The variable profile allows higher clinical performance within the constraints of SAR and power usage. [unreadable] [unreadable]

IC Name
NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING
  • Activity
    R43
  • Administering IC
    EB
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    99778
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    375
  • Ed Inst. Type
  • Funding ICs
    NCMHD:99777\NIBIB:1\
  • Funding Mechanism
  • Study Section
    ZCA1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    INVIVO CORPORATION
  • Organization Department
  • Organization DUNS
    009237140
  • Organization City
    GAINESVILLE
  • Organization State
    FL
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    32608
  • Organization District
    UNITED STATES