Wearable Ear Oxygenation

Information

  • Research Project
  • 9678518
  • ApplicationId
    9678518
  • Core Project Number
    R43DC017626
  • Full Project Number
    1R43DC017626-01
  • Serial Number
    017626
  • FOA Number
    PA-18-574
  • Sub Project Id
  • Project Start Date
    2/1/2019 - 5 years ago
  • Project End Date
    7/31/2019 - 5 years ago
  • Program Officer Name
    MILLER, ROGER
  • Budget Start Date
    2/1/2019 - 5 years ago
  • Budget End Date
    7/31/2019 - 5 years ago
  • Fiscal Year
    2019
  • Support Year
    01
  • Suffix
  • Award Notice Date
    1/10/2019 - 6 years ago
Organizations

Wearable Ear Oxygenation

PROJECT SUMMARY/ABSTRACT An estimated 60,000 mastoidectomies and 150,000 tympanoplasties are performed each year throughout the U.S, with published failure rates ranging from 3% to 26%[1-3]. One cause of failure is initial mucosalization in place of epithelialization at the wound site, leading to mucosalization of the mastoid cavity and tympanic membrane, with tympanic membrane perforation, mastoiditis, or otitis media as possible sequelae. According to Giner?s otolaryngologist consultants, Drs. Elizabeth Toh and Peter Weber, some form of the previous scenarios occurs in almost 100% of patients post-surgery, typically healing after 6 to 12 weeks under the current standard of post-surgical care ? packing the ear and using anti-biotic drops to prevent infection. For the approximate 10-20% of patients whose inflammatory process does not resolve, a surgical revision may be necessary. Drs. Toh and Weber believe that one possible way to decrease recovery time, dry the middle ear sooner by encouraging epithelialization over mucosalization, and prevent a revision surgery is to provide concentrated oxygen to the wound site. Giner has developed a miniature Electrochemical Oxygen Generator (EOG) under previous NIDDK funding for a bio-artificial pancreas; this proven technology would be further reduced in size and integrated into a hearing aid shell. Giner will also continue development of a self-regulating EOG and dosage control electronics to operate the device in order to provide a constant flow rate to the wound site. Additionally an ear piece will be developed that will provide a path for oxygen entry into the ear. The objective of this Phase I SBIR is to create 10 wearable Ear Oxygenation Devices (EODs), each with their own electronics and ear piece. These devices will be operated in vitro for a minimum of 15 weeks to demonstrate compatibility with the current recovery time, plus a safety margin.

IC Name
NATIONAL INSTITUTE ON DEAFNESS AND OTHER COMMUNICATION DISORDERS
  • Activity
    R43
  • Administering IC
    DC
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
    222005
  • Sub Project Total Cost
  • ARRA Funded
    False
  • CFDA Code
    173
  • Ed Inst. Type
  • Funding ICs
    NIDCD:222005\
  • Funding Mechanism
    SBIR-STTR RPGs
  • Study Section
    ZRG1
  • Study Section Name
    Special Emphasis Panel
  • Organization Name
    GINER, INC.
  • Organization Department
  • Organization DUNS
    066594979
  • Organization City
    NEWTON
  • Organization State
    MA
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    024661311
  • Organization District
    UNITED STATES