HIGH MASS RESOLUTION FOR MALDI TOF MASS SPECTROMETRY

Information

  • Research Project
  • 2649433
  • ApplicationId
    2649433
  • Core Project Number
    R43GM057736
  • Full Project Number
    1R43GM057736-01
  • Serial Number
    57736
  • FOA Number
  • Sub Project Id
  • Project Start Date
    4/1/1998 - 27 years ago
  • Project End Date
    3/31/1999 - 26 years ago
  • Program Officer Name
  • Budget Start Date
    4/1/1998 - 27 years ago
  • Budget End Date
    3/31/1999 - 26 years ago
  • Fiscal Year
    1998
  • Support Year
    1
  • Suffix
  • Award Notice Date
    3/2/1998 - 27 years ago
Organizations

HIGH MASS RESOLUTION FOR MALDI TOF MASS SPECTROMETRY

The use of ion formation methods such as matrix-assisted laser desorption/ionization (MALDI) in tandem with mass spectrometry (MS) has revolutionized the characterization of biologically significant molecules. MS has now become an indispensable technique for the analysis of large molecules such as lipids, peptides, proteins and nucleic acids. The ToF mass analyzer is widely used because of its simplicity, quasi-parallel detection and theoretically unlimited mass range. One historical drawback to the use of ToF is poor mass peak resolving power. The ability to resolve mass peaks is critical to the success of using accurate mass measurement to assign peak composition and structure. We feel the best approach to improving MALDI mass resolution is to decouple the ionization and extraction from acceleration and mass analysis by adding an interstitial collisional cooling stage. The proposed instrument design should markedly improve the resolution of MALDI mass spectra. To further improve resolution and timing accuracy and mass measurement accuracy, we will use the IOnwerks multi-channel time-to-digital converter (TDC). The combination of multi-pixel detector and multi-channel TDC will increase the dynamic range of the TDC data recorder to the point that it should compete with transient digitizers, but provide superior timing resolution. PROPOSED COMMERCIAL APPLICATION MALDI mass spectrometry is widely and effectively used in all aspects of biomolecule characterization. Should Phase I be successful, we will provide an instrument with mass resolution and mass accuracy superior to currently available instrumentation. We envision that the instrument will be immediately marketable to the biotechnology and pharmaceutical industries with applications as wide ranging as research scale protein scale protein assay to small scale clinical diagnosis.

IC Name
NATIONAL INSTITUTE OF GENERAL MEDICAL SCIENCES
  • Activity
    R43
  • Administering IC
    GM
  • Application Type
    1
  • Direct Cost Amount
  • Indirect Cost Amount
  • Total Cost
  • Sub Project Total Cost
  • ARRA Funded
  • CFDA Code
    821
  • Ed Inst. Type
  • Funding ICs
  • Funding Mechanism
  • Study Section
    ZRG3
  • Study Section Name
  • Organization Name
    IONWERKS, INC.
  • Organization Department
  • Organization DUNS
    154074553
  • Organization City
    HOUSTON
  • Organization State
    TX
  • Organization Country
    UNITED STATES
  • Organization Zip Code
    77002
  • Organization District
    UNITED STATES